OPTIONAL INSTALLATIONS
DIMENSIONS AND CLEARANCES
To ensure accuracy, it is best to make a template
when cutting the opening in the counter.
HORIZONTAL INSTALLATION WITH CONTROLS
AT THE FRONT
In this installation, the cooktop must be installed
with the control knobs toward the front edge.
VERTICAL INSTALLATION MUST BE ORIENTED
WITH CONTROLS ON THE LEFT SIDE
To eliminate the risk of burns by reaching over a
heated surface, the cooktop must be installed with
the controls on the left side.
In this installation, countertops must be at least 25
deep. Observe all minimum clearances at the front,
rear and sides.
4
15
Installation Instructions
The following MINIMUM clearance dimensions
must be maintained.
1
PREPARING THE OPENING
OVERALL COOKTOP DIMENSIONS
2
One and one-half inches
(1-1/2) minimum vertical
clearance between
the cooktop bottom
and any combustible
surfaces.
3
13 MAX. depth of unprotected
overhead cabinets
30 MIN.
clearance from
countertop to
unprotected
overhead surface
1-3/4 MIN. clearance
from cutout to side wall
on the left of the unit
18 MIN. height
from countertop
to nearest cabinet
on either side
of unit
1-3/4 MIN.
clearance from
cutout to side
wall on the right
of the unit
19-15/16
Cooktop
21-1/2
15-15/16
1-1/2 Min.
Vertical Clearance
2-3/4 MIN.
from front edge
of cutout and
front edge of
countertop
16-1/8 depth
of cutout
2 MIN. between
cutout and the
wall behind
the cooktop
If a 30 clearance between the cooking surface
and overhead combustible materials or metal
cabinets cannot be maintained, a minimum
clearance of 24 is required and the underside
of the cabinets above the cooktop must be
protected with not less than 1/4 insulating
millboard covered with sheet metal not less
than 0.0122 thick.
17-1/8
3
2-3/4 MIN.
from front edge
of cutout and
front edge
of countertop
20-1/8 depth
of cutout
16-1/8
width
of cutout
2 MIN. between
cutout and the
wall behind
the cooktop
1-3/4 MIN.
clearance from
cutout to left or
right side walls
1-3/4 MIN.
clearance from
cutout to left or
right side walls
20-1/8
width
of cutout
Zobrazit stránku 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 79 80

Komentáře k této Příručce

Žádné komentáře

Cortelco Telefone Benutzerhandbücher

Beginnend mit C

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
C ALLER ID T YPE II
Bedienungsanleitung   Cortelco C ALLER ID T YPE II User Manual, 28 Seiten
CALLER ID TYPE 2 9120
Bedienungsanleitung   Cortelco CALLER ID TYPE 2 9120 User Manual, 24 Seiten
CALLER ID TYPE II 2700
Bedienungsanleitung   Cortelco CALLER ID TYPE II 2700 User Manual, 24 Seiten
Caller ID Type II Multi-Feature Telephone 2705
Bedienungsanleitung   Cortelco Caller ID Type II Multi-Feature Telephone 2705 User Manual, 26 Seiten
CENTURION
Bedienungsanleitung   Cortelco CENTURION User Manual, 16 Seiten
CENTURION EXTENDED BASIC TELEPHONE
Bedienungsanleitung   Cortelco CENTURION EXTENDED BASIC TELEPHONE User Manual, 16 Seiten
Colleague 2200
Bedienungsanleitung   Cortelco Colleague 2200 User Manual, 28 Seiten
Colleague 2201
Bedienungsanleitung   Cortelco Colleague 2201 User Manual, 16 Seiten
Colleague 2211
Bedienungsanleitung   Cortelco Colleague 2211 User Manual, 22 Seiten