GE Induction Technický list Strana 1

Procházejte online nebo si stáhněte Technický list pro ne GE Induction. GE Induction Specification Sheet Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 2
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
INDOOR LIGHTING
Guide Form Specifications 2011
g
GE
Lighting Solutions
GUIDE FORM SPECIFICATIONS
GENERAL DESCRIPTION
GARAGE GUARDIAN
LUMINAIRE INDUCTION
Low Bay Enclosed
MECHANICAL CONSTRUCTION
BALLAST OPERATION
OPTICAL ASSEMBLY
The complete luminaire designated _____ (identify) shall be
a GE GARAGE GUARDIAN™ luminaire with, ordering number
_____ (specify GBP or GBC, plus ordering number logic from
catalog) or approved equal, to operate one _____ (specify [85]
watt QL Induction) lamp/ballast from a nominal120volt 60 Hz or
50 Hz power source. The luminaire shall include a completely
prewired integral ballast and optical assembly. The luminaire
shall be suitable for continuous service indoors in a maximum
ambient temperature of 40
°
C. The luminaire shall be UL Listed
SUITABLE FOR DAMP LOCATIONS or UL LISTED FOR WET LOCA-
TIONS depending on mounting, and C-UL,(Canadian) Listed for
Indoor Locations.
The luminaire shall be shipped as a completely assembled
fixture (Induction lamp installed).
The ballast housing and optical assembly shall be provided
with easy-to-read moisture-resistant nameplates which can be
seen without disturbing the installed luminaire.
The luminaire shall include provision for optional field mounting
of safety chain.
The ballast housing shall be made of die-cast aluminum. The
ballast housing shall have a polyester powder paint finish .
The luminaire shall include a _____ (specify mounting code)
mounting from the following optional mounting configurations:
10 = Surface Mtg. (Junction-box not included)
11 = 3/4" Rigid Pendant
12 = 3/4" Pendant With Bird Shield*
13 = 3/4"Flex Pendant Adjustable
01 = Primary Electrical Disconnect With MPM-C
02 = Primary Electrical Disconnect With MPM-3PR
03 = Primary Electrical Disconnect With MPM-3PF
04 = Primary Electrical Disconnect With MPM-3PRFW
05 = Primary Electrical Disconnect With MPM-3PRTFW
06 = Primary Electrical Disconnect With MPM-WW
NOTE:
Bird Shield Adds 4.4" To Overall Height
* See GELS Product Selection Guide for MPM mounting details.
The luminaire shall contain a standard electro-magnetic ballast
(with high power factor) in full compliance with lamp-ballast
specifications available to the fixture manufacturer from the
lamp manufacturers at the time of fixture manufacture.
The ballast shall reliably start and operate the lamp in ambient
temperatures down to -20
°
F (-29
°
C).
The optical assembly shall be enclosed and gasketed to
prevent entrance of particulate contaminants. The refractor
shall be UV stabilized injection molded prismatic heat-resistant
acrylic or optional impact resistant polycarbonate optic and
lens.
The optical shall have downlight cutoff classification with up-
light window and either clear or painted lower refractor band;
and have optional field adjustable internal uplight shielding.
* REFER TO PRODUCT PAGE IN GELS PRODUCT CATALOG FOR
OTHER BALLAST SELECTIONS. FOR MORE DEFINITIVE ELECTRI-
CAL INFORMATION, REFER TO BALLAST SPECIFICATIONS IN
TECHNICAL DATA SECTION.
Zobrazit stránku 0
1 2

Shrnutí obsahu

Strany 1 - LUMINAIRE INDUCTION

INDOOR LIGHTINGGuide Form Specifications – 2011gGE Lighting SolutionsGUIDE FORM SPECIFICATIONSGENERAL DESCRIPTIONGARAGE GUARDIAN™ LUMINAIRE INDUCTION

Strany 2 - 1 6 9 4 3 5 3 3- - -- 8 8 8

gGE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and

Komentáře k této Příručce

Žádné komentáře

Procom DPF 2-4... manuals

Owner’s manuals and user’s guides for Accessories communication Procom DPF 2-4....
We providing 1 pdf manuals Procom DPF 2-4... for download free by document types: User Manual


Table of contents





More products and manuals for Accessories communication Procom

Models Document Type
GPS-C 2r-gsm-fm-... User Manual   Procom GPS-C 2r-gsm-fm-... User Manual, 2 pages
SMI-70-... User Manual   Procom SMI-70-... User Manual [en] , 2 pages
BPF 1-...-200 User Manual   Procom BPF 1-...-200 User Manual, 1 pages
PRO-DIPX 240-370-7-16-... User Manual   Procom PRO-DIPX 240-370-7-16-... User Manual, 2 pages
DPID-1800-18 User Manual   Procom DPID-1800-18 User Manual [en] , 1 pages
PCPI UMTS User Manual   Procom PCPI UMTS User Manual [en] , 2 pages
PRO-phy150-5 User Manual   Procom PRO-phy150-5 User Manual, 1 pages
CXL 900-6LW-... User Manual   Procom CXL 900-6LW-... User Manual, 2 pages
DPID-900-14-gsm User Manual   Procom DPID-900-14-gsm User Manual [en] , 1 pages
PRO-phy85-3 User Manual   Procom PRO-phy85-3 User Manual, 1 pages
CXL 2-1LW-... User Manual   Procom CXL 2-1LW-... User Manual, 2 pages
BRF 900-...-125 User Manual   Procom BRF 900-...-125 User Manual, 1 pages
PRO-phy450-8si-... User Manual   Procom PRO-phy450-8si-... User Manual [en] , 1 pages
BPF 24g-7 User Manual   Procom BPF 24g-7 User Manual, 1 pages
PRO-phy150-3di-... User Manual   Procom PRO-phy150-3di-... User Manual [en] , 1 pages
PRO-marhp2-4-3-2-12v User Manual   Procom PRO-marhp2-4-3-2-12v User Manual [en] , 1 pages
GPS-C r-fm User Manual   Procom GPS-C r-fm User Manual, 2 pages
CXL 1800-1-... User Manual   Procom CXL 1800-1-... User Manual [en] , 2 pages
PRO-phy85-2di-... User Manual   Procom PRO-phy85-2di-... User Manual [en] , 1 pages
DPF 8-6-4-8 User Manual   Procom DPF 8-6-4-8 User Manual [en] , 1 pages