System set-up
Figure 3-17 shows the concept of a two-dimensional
(2D) X-ray microscopy system
to inspect
small components consisting of a micro- or nanofocus X-ray tube, an X-Y-Z manipulator and
detector. The manipulator can be joystick- or CNC-controlled. Full automation is possible.
The geometric magnification can be controlled by the Z-axis. Closer to the tube results in a
larger magnification factor.
The set-up of figure 3-17 is used for flat components. For certain applications, dependent on
the geometry of the component, the so called “ovhm” technique (oblique view at highest mag-
nification) is in use.
In such cases an open transmission X-ray tube generates an adjustable oblique (angled) beam,
the detector is angled accordingly as illustrated in figure 4-17. Instead of tilting the sample,
which would result in a certain distance D that would limit the magnification factor, the beam
is tilted as
illustrated reducing D to almost zero.
180
D
Z
Y
X
0 -70°
Tube control
X-ray tube
Manipulator
Component
Detector (image chain)
Joystick / CNC
Image processing
Workstation
Fig. 3-17. System set-up for X-ray microscopy
Fig. 4-17. Oblique (ovhm) technique for maximum magnification.
Effect of focal dimensions
Figure 1-17 illustrates in one way the effect of focal spot size (unsharpness), figure 5-17
shows the same in another way for a micro- and nanofocus tube head.
Figure 6-17 shows the effect of focus size on images of a connection (wire diameter 25
micron) in an electronic package. Image A is taken with a focal spot size of 10 micron, image
B shows the result for a 5 micron focus and image C was taken with a focus of less than 1
micron. Details of approximately 250 nm are visible.
There are rules-of-thumb to determine resolution and potential defect detectability as
a function of focal spot size.
For large magnifications, exceeding 100x, the following applies:
resolution equals the focal spot size divided by two
detectability or feature recognition equals focal spot size divided by three
Focal spot : 10 microns 5 microns <1 micron
Fig. 6-17. Effect of spot sizes on image sharpness for different focal spot sizes
X-ray tube
Detector
Adjustable
detector position
Detector
ABC
Object
Source
Fig. 5-17. Effect of focal spot size on sharpness
Zobrazit stránku 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 113 114

Komentáře k této Příručce

Žádné komentáře

Cortelco Telefone Benutzerhandbücher

Beginnend mit C

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
C ALLER ID T YPE II
Bedienungsanleitung   Cortelco C ALLER ID T YPE II User Manual, 28 Seiten
CALLER ID TYPE 2 9120
Bedienungsanleitung   Cortelco CALLER ID TYPE 2 9120 User Manual, 24 Seiten
CALLER ID TYPE II 2700
Bedienungsanleitung   Cortelco CALLER ID TYPE II 2700 User Manual, 24 Seiten
Caller ID Type II Multi-Feature Telephone 2705
Bedienungsanleitung   Cortelco Caller ID Type II Multi-Feature Telephone 2705 User Manual, 26 Seiten
CENTURION
Bedienungsanleitung   Cortelco CENTURION User Manual, 16 Seiten
CENTURION EXTENDED BASIC TELEPHONE
Bedienungsanleitung   Cortelco CENTURION EXTENDED BASIC TELEPHONE User Manual, 16 Seiten
Colleague 2200
Bedienungsanleitung   Cortelco Colleague 2200 User Manual, 28 Seiten
Colleague 2201
Bedienungsanleitung   Cortelco Colleague 2201 User Manual, 16 Seiten
Colleague 2211
Bedienungsanleitung   Cortelco Colleague 2211 User Manual, 22 Seiten